How to read a well water test

A lab report is a list of names, numbers, and units. This page explains the columns the calculator uses. It does not include an example from a real well, because inventing one would look like a result.

Updated

Not health advice. If total coliform is present, or you do not understand a nitrate result, contact your local health department before you drink the water. A softener does not fix either one.

The columns

Most drinking-water reports have some version of these fields:

EPA asks private-well owners to test every year for total coliform bacteria, nitrate, total dissolved solids, and pH, and to add tests when there is a reason: staining, odor, nearby land use, or a plumbing change. University of Maryland Extension publishes its own panel and a three-year repeat for several metals and hardness. Use those lists to order the test. Use this page to read it.

Units the calculator needs

Hardness on a lab sheet is often milligrams per liter as calcium carbonate. The calculator asks for grains per gallon. USGS Water-Supply Paper 1895-B says grains per U.S. gallon can be calculated by dividing milligrams per liter by 17.1. The Maryland Geological Survey uses 17.118 mg/L per grain. For a shopping estimate, either factor is close. Write down which one you used.

USGS hardness classes, as calcium carbonate: soft, 0 to 60 mg/L; moderately hard, 61 to 120 mg/L; hard, 121 to 180 mg/L; very hard, more than 180 mg/L. The calculator starts recommending a softener at 61 mg/L, about 3.56 grains per gallon. Connecticut’s health department prints a finer scale that splits “slightly hard” out of the soft band. The calculator follows USGS, not that finer scale.

Iron in ppm and iron in mg/L are the same number at drinking-water concentrations. Hydrogen sulfide is the same. pH is already the unit the calculator wants. Peak flow in gallons per minute is not usually on a lab report. It comes from the fixtures, not the chemistry.

Secondary standards, labeled as standards

The table below is 40 CFR 143.3 and EPA’s secondary-standards page. It is the public-water nuisance guideline. It is not a TapSpec lab result, and it is not a health maximum. EPA says these contaminants are not considered a health risk at the secondary level. States can set different numbers.

On a small screen, scroll or swipe sideways to see every column.

Selected EPA secondary standards. Regulatory reference values, not sample results.
Analyte Secondary standard Why it is on this page
Iron 0.3 mg/L Staining and taste. The calculator still asks for the measured ppm, not a yes/no against 0.3.
Manganese 0.05 mg/L The Pentair chart adds 8 grains per ppm. The calculator applies that factor when you enter ppm. A blank is not zero.
pH 6.5–8.5 SpringWell’s published softener and well-filter range starts at 6.5. Below that, the calculator says those models are not confirmed.
Sulfate 250 mg/L Sulfate is not hydrogen sulfide. Do not type a sulfate number into the sulfur box.
Odor 3 threshold odor number A nuisance guideline. It is not a hydrogen sulfide concentration. If the lab reports H2S in ppm, use that ppm.
Total dissolved solids 500 mg/L EPA includes it in the annual private-well list. It is not a softener size.

Primary standards the softener will not solve

Nitrate’s national primary limit is 10 mg/L as nitrogen. That number lives on EPA’s primary drinking-water regulations, not in the secondary table. Total coliform is a bacteria test: a present or positive result is a reason to call the health department. University of Nebraska–Lincoln Extension lists both nitrate and bacteria among contaminants a softener does not remove. Do not shop for a grain capacity as a substitute for that call.

PFAS, if you tested it, is a yes, no, or a concentration you can discuss with the health department. The calculator’s PFAS box is only yes / no / unknown. Unknown does not add a PFAS filter. Yes adds a carbon stage and points you at EPA’s treatment list. Does a softener remove PFAS?

Chloramine is usually a city-water question. It is on a consumer confidence report more often than on a well test. If you are on a public system, look up the disinfectant before you pick a carbon filter. Aquasana tells chloramine customers to use the catalytic-carbon Rhino, not the standard one.

Then use the number

Hardness in grains, iron in ppm, hydrogen sulfide in ppm or blank, pH or blank, and peak flow if you know it. Open the calculator or import a PDF on this device. If the well is in Maryland, the agency context is on the Maryland and mid-Atlantic page.

Questions this page answers

Are mg/L and ppm the same on a well test?

For ordinary drinking-water concentrations, yes. A U.S. Geological Survey water-supply paper says that below about 12,000 mg/L of dissolved solids there is no significant difference between milligrams per liter and parts per million.

How do I convert hardness from mg/L to grains per gallon?

Divide mg/L as calcium carbonate by 17.1, the factor in that USGS paper, or by 17.118, the factor published by the Maryland Geological Survey. The TapSpec calculator wants grains per gallon.

Does a number over a secondary standard mean the water is unsafe?

No. EPA secondary standards are non-enforceable taste, odor, and color guidelines. EPA says these contaminants are not considered to present a health risk at the secondary level. A primary standard, such as nitrate, is a different column. This page does not interpret health risk.

Sources

  1. Summary of data on chemical quality of streams of North Carolina, 1943–67 (Water-Supply Paper 1895-B), reporting units — U.S. Geological Survey
  2. Hardness of water — U.S. Geological Survey
  3. Hardness in Maryland groundwater — Maryland Geological Survey
  4. Secondary drinking water standards: guidance for nuisance chemicals — U.S. Environmental Protection Agency
  5. 40 CFR 143.3, secondary maximum contaminant levels — U.S. Code of Federal Regulations
  6. Protect your home's water (private wells) — U.S. Environmental Protection Agency
  7. National primary drinking water regulations — U.S. Environmental Protection Agency
  8. Water testing — University of Maryland Extension
  9. Drinking water treatment: water softening (G1491) — University of Nebraska–Lincoln Extension
  10. Hardness fact sheet — Connecticut Department of Public Health
  11. Pentair American Plumber water softeners and automatic filters catalog, document 350040 REV C MR14, residential sizing chart — Pentair